QUIESCE (VSE Only) TSIDMNT Commands
3-34 User Reference
QUIESCE (VSE Only)
QUIESCE makes disk volumes ineligible for the creation of controlled datasets. BIM-EPIC
will not allocate output datasets on a volume that has been quiesced. Quiesced volumes are
still eligible for BIM-EPIC input processing and for uncontrolled processing. QUIESCE
cannot disable a volume across machines, so you must use QUIESCE on all machines that
have access to the volume.
Use the ONLINE command to remove a volume from quiesced status. Use the OFFLINE
command to remove a volume from both input and output processing.
QUIESCE
volser
Parameter Required? Valid Entry Default
volser
Yes 1 to 6 characters None
volser specify the serial number of the volume you want to quiesce.
The following example quiesces the disk volume SYSWK1.
QUI SYSWK1
Description
Syntax
Parameters
Example